Sign In | Join Free | My qualitytoyschina.com
China Qingdao Qingyuanfengda Import and Export Co., Ltd logo
Qingdao Qingyuanfengda Import and Export Co., Ltd
Quenda pays great attention to every customer and maintains a permanent cooperative relationship with them by providing reliable service and equipment.
Active Member

5 Years

Home > Spectroscopy System >

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction

Qingdao Qingyuanfengda Import and Export Co., Ltd
Contact Now

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction

Brand Name : Quenda

Model Number : QS-2830

Certification : CE,ISO

Place of Origin : QINGDAO,CHINA

MOQ : 1set

Price : USD10000-50000

Payment Terms : T/T

Supply Ability : 200set per month

Delivery Time : 7-10days

Packaging Details : Carton

Wavelength Range : 190nm~900nm

Spectral Bandwidth : 0.2, 0.4, 1.0, 2.0nm (automatic switching)

Number of Sample Cups : 50 sample cups(1.5mL); 2 reagent cups(10mL)

Sample Volume : 1~50μL

Repeatability : ≤0.5% (5~50μL)

Host Size(W*D*H) : 872mm*560mm*460mm

Contact Now

Atomic Absorption Spectrometer AAS With Deuterium lamp (D2) background correction

AAS Performance characteristics

  • The integrated design of flame graphite furnace can be switched with one key;

  • Deuterium lamp (D2) background correction.;

  • It is equipped with water seal detection, waste liquid level detection, gas pressure monitoring and flame monitoring;

  • It is equipped with perfect interlocking protection device and anti tempering device to automatically shut down the gas in case of accidental flameout;

  • Vertical 8-element lamp design, eight lamps are preheated at the same time;

  • 52 position graphite furnace automatic sampler;

  • Atomization system;

  • Titanium alloy combustion head, all plastic atomization chamber, corrosion resistance;

  • Glass atomizer is adopted, which is corrosion-resistant and easy to clean;

  • 10 step heating program, three heating modes: step, slope and hold;

  • Longitudinal heating technology.

AAS ​Technical Parameter

Power Supply 220V±10% AC; 300VA; 50Hz±1Hz
Operation Temperature 10℃~30℃
Technical Condition Operation Humidity ≤ 75%
Host Size(W*D*H) 872mm*560mm*460mm
Weight 85kg
Wavelength Range 190nm~900nm
Spectroscopic System

Monochromator

Optical Grating

C-T (Czerny-turner)type; Focal length: 270mm

1800 pieces/mm

Spectral Bandwidth 0.2, 0.4, 1.0, 2.0nm (automatic switching)
Number of Sample Cups 50 sample cups(1.5mL); 2 reagent cups(10mL)
Sample Volume 1~50μL
Repeatability ≤0.5% (5~50μL)
AS-100 Automatic Sampler

Power Requirement

Size(W*D*H)

DC24V; 40W

350mm*280mm*180mm

Weight Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction inclined injection
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction single injection pump
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction 5℃~35℃
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction ±1℃
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction 900W @25℃
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction 8L
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction 0.05Mpa~0.15Mpa
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction 2-10L/min
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction 360mm*450mm*660mm
Power Supply 220V±10% AC; 50Hz
Output Power/Speed 600W/1400V/min
Starting Pressure Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction
YH-04 Low Noise Oil-free Air Compressor

0.75mp

60L/min(0.4mp)

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction 28L
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction <58dB(A)
Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction


Authentication

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction

Exhibition

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction


Instrument commissioning and training

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction

Customer visit

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction

Add: No.151, Zhuzhou Road, Laoshan District, Qingdao, Shandong, China


Product Tags:

Atomic Absorption Spectrometer AAS

      

Deuterium Lamp Atomic Absorption Spectrometer

      

Background Correction Spectroscopy System

      
Quality Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction wholesale

Atomic Absorption Spectrometer AAS With Deuterium Lamp (D2) Background Correction Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Qingdao Qingyuanfengda Import and Export Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)